CCTV 2+1 AL 2×0,22 mm²

58
Application
These cables are used in closed circuit TV viewing, visual telephone systems and video sytems.
Construction
1. Coax. Inner conductor 7×0,16 mmØ (0,14 mm²) Stranded annealed copper or tinned copper wire (IEC 60228)
2. Coax. Insulation Approx. 2,50 mmØ Foamed polyethylene
3. Coax. I. and II. Screen %100 AL-PES tape shielded ve Aluminium wire braid
4. Control Conductive 7×0,20 mmØ (0,22 mm²) Stranded annealed copper or tinned copper wire (IEC 60228)
5. Control Insulation PVC insulated (EN 50290-2-) Red, Blue colour
6. Overall Screen Screening is made by combining coaxial cable and the control cores to each other by the appropriate pitch and then by screening this combination with Al-PES.
7. Outer Sheath 5,50 mmØ PVC / HFFR / PE (EN 50290-2), PVC – RAL 7001 Grey / HFFR – RAL 7001 Grey / PE – Black
General Features
Flame Retardent
(For Single Cable)
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Halogen Acid Gas Test IEC 60754-1, EN 50267-2-1,VDE 0482-267-2-1
(for HFFR)
Acidic (Corrosive)
Gas Test
IEC 60754-2, EN 50267-2-2,
VDE 0482-267-2-2 (for HFFR)
Smoke Density Test IEC 61034-2, EN 61034-2, VDE 0482-1034-2
(for HFFR)
Technical Properties
Temperature Range -30 °C …. +70 °C
Operating Voltage Max. 300 V
Test Voltage 1200 V
Min. Bending Radius 15xD (D:Cable Diameter)